Activity

Activity ID

10273

Expires

November 7, 2025

Format Type

Journal-based

CME Credit

1

Fee

$30

CME Provider: JAMA Otolaryngology – Head & Neck Surgery

Description of CME Course

Importance  Despite growing scientific knowledge and research, it is still unknown if office flexible laryngoscopy (FL) is aerosol generating and thereby potentially increases the risk of SARS-CoV-2 transmission. The limited literature that exists is conflicting, precluding formal conclusions.

Objective  To determine whether FL is aerosol generating.

Design, Setting, and Participants  This prospective cohort study included 134 patients seen in the otolaryngology clinic at a single tertiary care academic institution between February and May 2021. Two optical particle sizer instruments were used, quantifying particles ranging from 0.02 μm to 5 μm. Measurements were taken every 30 seconds, with sample periods of 15 seconds throughout the patient encounter. Instruments were located 12 inches from the patient’s nares. Timing of events was recorded, including the start and end of physical examination, topical spray administration, start and end of laryngoscopy, and other potential aerosol-generating events (eg, coughing, sneezing). Data analysis was performed from February to May 2021.

Exposures  Office examination and office FL.

Main Outcomes and Measures  Bayesian online change point detection (OCPD) algorithm was used to detect significant change points (CPs) in this time-series data. The primary outcome was significant CP after FL compared with baseline physiologic variations, such as breathing and phonation.

Results  Data were collected from 134 patients between February and May 2021. Ninety-one encounters involved FL. Of this group, 51 patients (56%) wore no mask over their mouth during FL. There was no statistically significant CP in either visits involving FL or visits where FL was not performed. Use of nasal spray did not result in CP in aerosol levels. Overall, neither the number of people present in the examination room, masks over patients’ mouth, the duration of the visit, nor the duration of FL were associated with mean aerosol counts, regardless of the exposure. For larger aerosol sizes (≥1 μm), however, rooms with higher air exchange rates had significantly higher reductions in mean aerosol counts for visits involving FL.

Conclusions and Relevance  The findings of this cohort study support that FL, including topical spray administration, is not a significant aerosol-generating procedure. The Bayesian OCPD model has a promising application for future aerosol studies in otolaryngology.

Disclaimers

1. This activity is accredited by the American Medical Association.
2. This activity is free to AMA members.

Register for this Activity

ABMS Member Board Approvals by Type
More Information
Commercial Support?
No

NOTE: If a Member Board has not deemed this activity for MOC approval as an accredited CME activity, this activity may count toward an ABMS Member Board’s general CME requirement. Please refer directly to your Member Board’s MOC Part II Lifelong Learning and Self-Assessment Program Requirements.

Educational Objectives

To identify the key insights or developments described in this article

Keywords

Coronavirus (COVID-19), Otolaryngology

Competencies

Medical Knowledge

CME Credit Type

AMA PRA Category 1 Credit

DOI

10.1001/jamaoto.2022.3316

View All Activities by this CME Provider

The information provided on this page is subject to change. Please refer to the CME Provider’s website to confirm the most current information.